Heat Exchanger for Chiller

Custom-designed heat exchangers for industrial chillers, engineered for efficient heat transfer, reliable cooling performance, and long-term operation across demanding applications.

Product Overview

A process chiller is not an air conditioning system with an industrial label. Process cooling often has tight temperature tolerances, aggressive fluids, violently variable loads, and a cost of downtime measured in scrapped production rather than discomfort.

Southern Coil manufactures customised fin-and-tube heat exchangers for industrial process chillers, covering both sides of the machine: air-cooled condenser coils that reject heat to ambient, and fluid coils that cool water, glycol, oil or process media. Both are built to the capacity, fluid, operating conditions and physical envelope of the equipment they serve.

Because process chillers are frequently built around the space available rather than around a standard component, customisation is usually the requirement rather than an upgrade. We work from a drawing, an existing coil, or simply the duty and the constraint — and where the fluid is unusual or aggressive, material selection is settled before any thermal calculation begins.

Coils are manufactured in copper tube with aluminium fin as standard, with alternative materials, frames and coatings specified for the process environment. Every coil is 100% nitrogen leak tested — typically to 600 psi, and higher where the application’s working and maximum pressure require it. Southern Coil is certified to ISO 9001:2015 and holds ZED Silver Certification, both covering all products.

Key Features

Built for the Chiller, Not Adapted to It

Custom-designed coils from 6 inches to 6 metres and beyond, including very large coils, based on the available installation space.

Fluid and Refrigerant Duty

Suitable for water, glycol mixtures, thermal oils, brines, process media, and DX refrigerant circuits.

Glycol-Corrected Selection

Glycol concentration and fluid properties are considered during coil selection for accurate performance.

Pressure Drop Designed as a Constraint

Coils are selected according to the available pump head while meeting the required cooling performance.

Multiple Tube Diameter Options

Available in 7 mm, 3/8″, and 1/2″ copper tubes, with plain or inner-grooved options in 7 mm and 3/8″.

Flexible Fin Density

Fin density from 4 to 17 FPI, with wider spacing and flat fins available for contaminated plant-air environments.

Fouling Allowance

Coil selection can include fouling allowances where fluid-side or air-side conditions require additional consideration.

Multiple Frame & Coating Options

Frames available in galvanised iron, aluminium, stainless steel (304 or 316), or plastic, with anti-corrosion and sprayed epoxy coating options.

Precision Manufacturing & Testing

Controlled tube expansion, nitrogen-purged brazing, and 100% nitrogen leak testing for every coil.

Applications

Heat exchangers for industrial chillers are suitable for a wide range of process cooling applications where reliable heat transfer and temperature control are essential.

  • Industrial Process Chillers
  • Injection Moulding & Plastics Processing
  • Machine Tool & Spindle Cooling
  • Laser & CNC Equipment Cooling
  • Chemical & Pharmaceutical Process Cooling
  • Food & Beverage Process Cooling
  • Electroplating & Surface Treatment
  • Hydraulic & Lubrication Oil Cooling
  • Printing & Packaging Lines
  • OEM Chiller Manufacturing

Custom-engineered to meet specific dimensions, fluid requirements, cooling capacity, operating conditions, and installation constraints.

Technical Specifications

Tube Diameters
1/2″ (12.7 mm) | 3/8″ (9.52 mm) | 7 mm

Tube Type
Plain or inner-grooved (7 mm and 3/8″); plain (1/2″)

Tube Material
Copper

Fin Material
Aluminium — plain or hydrophilic; copper on request

Fin Geometry
Straight edge, zig-zag, louvred

Fin Density
4 to 17 fins per inch

Frame Material
Galvanised iron, aluminium, stainless steel (304 or 316 on request), plastic

Coil Size
6 inches to 6 metres and beyond

Fluids
Water, ethylene and propylene glycol, thermal oils, brines, process media, refrigerants

Why Glycol Concentration Changes the Design

Glycol is added for freeze protection, and every percentage point of it costs heat transfer.

A glycol mixture has lower thermal conductivity and specific heat than water, and substantially higher viscosity — and viscosity rises sharply as temperature falls, which is exactly the condition a low-temperature process chiller operates in. Higher viscosity suppresses turbulence, and turbulence is what makes the in-tube heat transfer coefficient useful.

A coil designed for water and then run on 40% glycol will under-deliver on capacity and exceed its design pressure drop, which in turn affects pump selection.

Ethylene and propylene glycol are also not interchangeable. Propylene is preferred where toxicity matters — food and pharmaceutical work — but it is more viscous and carries a larger heat transfer penalty at the same concentration.

Tell us the fluid and the concentration. It is not a detail, and assuming water where glycol is used is one of the most common causes of a coil that appears to underperform.

Why Choose Southern Coil

Built Around Custom Manufacturing

Every coil we manufacture is designed around your application—not adapted from a standard catalogue. This provides greater flexibility in dimensions, performance, and installation.

Production You Can See

Our proprietary production management system provides customers with live visibility into manufacturing progress, enabling better planning and improved communication throughout production.

Commitments Based on Data

Delivery dates are determined using live production schedules and capacity planning rather than assumptions. Our objective is to provide delivery commitments that are realistic, dependable, and consistently achieved.

Modern Manufacturing Infrastructure

Our facility combines precision machinery with digital production management to deliver repeatable quality across every batch. Investments in automation, tooling, and production planning help improve consistency while reducing waste.

Quality at Every Stage

Quality is built into the manufacturing process—not inspected only at the end. Every coil passes through defined checkpoints covering dimensional accuracy, brazing quality, pressure testing, and final inspection before dispatch.

ZED Silver Certified

Southern Coil Industries is proud to be ZED (Zero Defect Zero Effect) Silver Certified, reflecting our commitment to quality manufacturing, sustainable operations, resource efficiency, and continuous improvement.

An Engineering Partner

We work closely with OEMs, refrigeration equipment manufacturers, and HVAC system designers throughout the product development process, helping optimize designs for manufacturability, performance, and long-term reliability.

 

Frequently Asked Questions

Yes. Provide the glycol type and concentration along with the temperatures and flow rate, and the selection will be corrected for the fluid properties rather than calculated on water.

Yes — this is the normal case. Coils are made to order from 6 inches to 6 metres and beyond, including very large coils, and the envelope is treated as a hard constraint that the design works within.

There is no catalogue capacity range, because nothing is built to a catalogue. Coils are designed to the duty and the envelope you give us, and size is rarely the limiting factor. Send us the requirement and we will tell you directly whether it is something we can build.

Yes. We manufacture air-cooled condenser coils and fluid-side coils for process chillers, as well as oil coolers and chilled water coils.

Coils are supplied unfilled and uncharged — charging is carried out by the equipment manufacturer or the installer.

 

Usually. Send the fluid datasheet or its properties at operating temperature, along with any material compatibility restrictions. Some fluids rule out copper or aluminium, and that is established before the thermal design.

Not at present. Ammonia attacks copper, and our coils are built in copper tube, so ammonia duty is outside our current scope. If your system uses ammonia on one side and a secondary fluid such as glycol on the other, the secondary-fluid coil is something we can build.

Request a Quote

Need a custom heat exchanger for your chiller application?

Share your required dimensions, fluid type, cooling capacity, flow rate, operating conditions, or drawings, and our engineering team will help develop a heat exchanger solution tailored to your requirements.

For nearly three decades, we have relentlessly pursued the perfection of heat exchangers, to become the premier manufacturer in South India. Our journey, commencing in 1994, has seen us meticulously craft a robust manufacturing infrastructure, setting the foundation for our excellence.

Address

Survey No: 50/15B, Nemili Road,
Sriperumbudur Taluk,
Kanchipuram District,
Pincode - 602105,
Tamil Nadu, India
+91 89392 77606
info@southerncoil.com